ENGINEERED
STEEL PRODUCTS |
Priced
Full Line Products Catalog |
20
Technology Way West Greenwich, RI 02817
Toll free:(800) 421-0314 In RI:(401) 272-4570 Fax:(401)
421-5679 |
|
|
|
Back to Product Category
DUAL
MAST MEZZANINE LIFT
|
VRC
|
|
Dual Mast Mezzanine Lift (Vertical Reciprocating Conveyor)
provides
extra strength for heavy loads up to 12,000 pounds and
offers a variety
of larger platform carriage sizes up to 12' x 12'. This
lift is great when
overhead space is limited because it only requires 7'2"
of height above
the upper level. Also, it can be loaded and unloaded from
the front or
the rear. |
|
|
|
|
|
Made
Especially For... |
|
Warehousing/Storage
Facilities, Manufacturing Facilities, Paper and
Textile Industries, Aerospace Industry, Military Bases,
Ships and
Marine Vessels to name a few. |
|
|
|
|
Standard
Features... |
|
|
Travel Height: Up to 90'
Operating Speed: 30 fpm
Power Requirement: 230v 3-phase 60 hertz
Operator controls at each level
Upper and Lower Travel Limit Switches
Fail-Safe Brake Motors
Chain Safety Brakes
Slack Chain Switches
Soft Start/Soft Stop Operation
Mount: Surface or Pit |
|
|
|
|
|
For
Heavy Loads In Height
Restricted Areas
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Options
|
|
|
Technical
Specifications |
Operating
Speed Increased
Power - 460v 3-phase 60 hertz Ground Level Loading Ramp
Security Enclosures
Gates with Electro -
Mechanical Interlocks
Multi - Level Operation
Special Environments |
|
Technical
Specifications for the Dual
Mast Mezzanine Lift are shown below.
Please fill in your desired specifications
in the spaces provided. Contact us for
special requirements or configurations.
|
|
|
|
1.
What weight capacity do you require?
(1,000 - 12,000 lbs.) _____________ |
|
2.
What is the height in inches from the
ground level floor surface to
the
second level floor surface?
(Up to 90') __________________ |
|
|
Platform
Carriage Side
Rails Enclosures
|
|
3.
Platform carriage size:
4' - 12' (w) x 4' - 12' (d) ___________ |
|
4.
What platform load height do you
require? 72"(h) standard;
78"(h) max.
through doors. _______________
|
48"(h)
on non-access openings,
snap chains on access ends
|
|
|
5.
Which load / unload configuration
do you require? ____ C _____Z |
|
|
|
|
|
6.
How will the unit be mounted?
___surface ___ pit |
|
|
|
Surface
Mount: |
|
The
loading height is 6"-8" from the floor
on the ground level and flush with the
floor on the upper levels. |
|
|
|
|
|
|
|
Pit
Mount: |
|
|
Loading
height is flush with the floor on
all levels. (Standard Dual Mast Pit Depth
is 6" - 8".) |
|
|
|
Note: |
|
|
|
Our
mezzanine lifts are manufactured to ANSI/ASME B20.1 safety
standards. They are not subject to elevator codes as they
are
designed for material lifting only. No personnel are permitted
to ride on any mezzanine lift. The following items are
to be supplied by
others and are not included with the mezzanine lift: (1)
Wall and floor hardware to secure the lift to the walls
and floor, (2) External
electrical wiring which is to be performed by a qualified
electrician to local and national codes, (3) Conduit and
disconnect switch
that is required to connect to our control panel, (4)
Upper and lower thresholds. |
|
|
|
|
|
|
|
|
|
|
|
Illustrated
As A 2-Level Lift with
Optional Security Enclosures;
Multi-Level Versions are Available |
|
|
|
|
|
ARCHITECTURAL
SPECIFICATIONS
VERTICAL RECIPROCATING CONVEYOR
|
|
|
|
|
|
PART
1: GENERAL |
|
|
|
|
|
|
1.01:
OVERVIEW |
|
|
A. Design and manufacturing of one (1) dual mast type
Vertical Reciprocating Conveyor (VRC) including
mechanical drive unit, operator
controls, safety gates and enclosures as shown on project
drawings and
as specified herein. |
|
|
|
|
|
1.02:
REFERENCES |
|
|
|
|
|
|
|
|
A.
ANSI - American National Standards Institute (ANSI B20.1) |
|
B.
ASME - American Society of Mechanical Engineers (ASME
B20.1) |
|
C.
NEMA - National Electrical Manufacturer's Association |
|
|
|
|
|
1.03:
SUBMITTALS |
|
|
|
|
|
|
|
|
A.
Product Data: Submit latest edition of Dual Mast VRC datasheet
and general drawings with the proposal. |
|
|
|
|
|
|
B.
Customer Drawings: |
|
|
|
|
|
|
|
1.
Submit Customer Engineering Drawings for customer approval
within 2 weeks after receipt of an order to
include plans, elevations, sections of the VRC, base plate
and lateral loading values, and recommended pit
dimensions if applicable. |
|
|
|
|
|
|
|
2.
Submit VRC Specification Sheet for approval within two
weeks of receipt of an order to include scope
of work, operating and control voltages, lift speed, type
of finish, and any special project notes. |
|
|
|
|
|
|
C.
Closeout Submittals provided with VRC Equipment: |
|
|
|
|
|
|
|
1.
Electrical Schematics Drawing including control panel
layout and Bill of Material reflecting original
manufactured part numbers. |
|
|
2.
Mechanical Installation Manual and Electrical Installation
Guide. |
|
|
3.
Digital Control Panel trouble shooting guide. |
|
|
4.
Owner's Manual including replacement parts list, exploded
parts drawings, operating instructions,
maintenance schedule, and service and troubleshooting
guidelines. |
|
|
|
|
|
1.04:
QUALITY ASSURANCE |
|
|
|
|
|
|
|
|
A.
Manufacturer must have a minimum of five (5) years experience
in the manufacturing of vertical
reciprocating conveyors. |
|
B.
Vertical Reciprocating Conveyors (VRC) are covered by
ANSI/ASME B20.1 Safety Standards for Conveyors.
We have thousands of vertical lifts installed throughout
the country and in surrounding countries. NO VRC has ever
been shut down due to lack of elevator code compliance.
|
|
C.
Installer must have the approval of FSI and have a minimum
of five (5) years experience in the installation
of vertical material lifts. |
|
|
|
|
|
1.05:
WARRANTY |
|
|
|
|
|
|
|
|
A.
The manufacturer shall warrant the VRC against manufacturing
defects from date of installation as outlined
below: |
|
|
|
|
|
|
|
1.
Electric Motor and Cyclo-Drive Reducer - two (2) years. |
|
|
2.
Electrical Components - ninety (90) days. |
|
|
3.
Mechanical Components - one (1) year. |
|
|
|
|
|
PART
2: PRODUCTS |
|
|
|
|
|
|
|
2.01:
VRC MECHANICAL SPECIFICATIONS |
|
|
|
|
|
|
|
A.
Load Capacity: The VRC shall be rated at a live load capacity
of _______ lbs. |
|
|
B.
Operating Speed: The VRC shall have a vertical lifting
speed of 20 - 25 feet per minute when loaded to
maximum capacity. |
|
|
C.
Vertical Travel Height: The VRC shall have a vertical
lifting height of _____ inches with a total of _____
landings (including lowest level) with a distance between
floors of ______ inches. |
|
|
D.
Lift Carriage: The VRC carriage shall be a minimum of
_____ inches wide x _____ inches deep
with a steel deck plate and minimum of 48" high welded
or bolt-on side panels on all non-operating ends
and safety chains with snap hooks on all operating ends. |
|
|
E.
Vertical Masts: The VRC shall have a two (2) support mast
constructed of four (4) 4" square structural grade
steel tubes for vertical support and strengthened by horizontal
2" square steel tubes. |
|
|
F.
Deflection Under Load: No portion of the VRC shall exhibit
permanent deflection when loaded to full capacity. |
|
|
G.
Shock Load: The VRC must be able to withstand a shock
load of at least 500% to ensure safety. |
|
|
H.
Lifting Means: The drive system shall be comprised of
four (4) sprockets transmitting lifting forces through
four (4) chains to the back section of the carriage. The
electrical drive motors shall be 100% duty cycle coupled
with a Cyclo-Drive gear reducer with a shock load rating
of 500%. Planetary or helical gear reducers are not
allowed. |
|
|
I.
Safety Brakes and Devices: The Carriage shall be equipped
with one (2) broken/slack chain brake that
prevents the carriage from descending more than 6"
if tension is lost on either chain. Slack chain switches
are
required to disable motor power in the event a chain becomes
slack or broken. |
|
|
J.
Security Enclosures: Guarding on all non-operating sides
of the VRC shall be by security enclosures extending
a minimum of 8' high at each level consisting of expanded
metal which will reject a ½" diameter ball.
Security
enclosures shall tie directly into the vertical mast for
added structural support. |
|
|
K.
Landing Gates: Gates are required on all operating sides
of the VRC at each level of operation. |
|
|
|
1.
The gates shall be (double swing) (vertical slide) (horizontal
slide) (roll-up) type. |
|
|
|
2.
Each gate must be equipped with an elevator approved electro-mechanical
interlock to prevent opening
of the gate unless the carriage is present and to prevent
operation unless all gates are closed. |
|
|
L.
Signage: Signs dictating "NO RIDERS" and maximum
weight capacity shall be placed at every access point
and visible from all operating ends of the carriage. |
|
|
M.
Approach Ramp: If pit mounting is not specified, the manufacturer
shall supply a steel fabricated 8" high
approach ramp to be installed within ½" of
the VRC carriage at the ground level. |
|
|
N.
Power Requirements: The VRC shall be manufactured to operate
on 230 volts / 3 phase / 60 hertz power.
Controls voltage must be no greater than 24 volts. |
|
|
O.
Load Pattern: The pattern for loading and unloading the
carriage at different levels must be a "Z" or
"C"
configuration. |
|
|
|
|
|
2.03:
VRC ELECTRICAL SPECIFICATIONS |
|
|
|
|
|
|
|
|
|
|
|
|
|
A.
Electric Motor: |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
1. Each of two (2) motors shall have a minimum duty cycle
of 100%. |
|
|
|
2.
Each motor and Cyclo-Drive gear reducer must be able to
withstand a shock load of at least 500% to ensure
safety. |
|
|
|
3. Motor horsepower shall be sized to handle the carriage
weight in addition to the rated live load and
specified speed. |
|
|
|
4.
All motors are three phase and shall be designed for continuous
duty at ambient temperatures for 32° to 102°
Fahrenheit |
|
|
|
5.
The motors shall not automatically restart when the overload
device is reset. |
|
|
|
6.
Each motor shall be equipped with a heavy-duty, long life,
fast-acting fail-safe disc brake to ensure the brake
will hold in case of power failure. |
|
|
|
|
|
|
|
|
|
|
|
|
B.
Controls: |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
1.
Each operating floor shall be equipped with a momentary
contact push-button control station with full call,
send and mushroom style E-stop switches for manual control
of lift operation. |
|
|
|
2.
An internally pre-wired, NEMA 12 rated Intelitroll self-diagnostic
control panel shall be provided with
appropriate transformer, overload relay, phase monitor
device, field wiring terminal block and breakers. |
|
|
|
3.
Limit Switches: The VRC shall be equipped with a floor
level switch at each level, upper level, and over
travel limit switch to provide precise positioning of
the carriage. |
|
|
|
4.
Slack Chain Safety Switches: Two switches shall be provided
to monitor slack chain situations and disable
power to the motor while engaging carriage safety brakes
in the event of a slack or broken chain. |
|
|
|
5. The control voltage shall not exceed 24 volts for safety
reasons. |
|
|
|
|
|
|
|
|
|
|
|
|
C.
Power Source: Owner shall terminate high voltage operating
power within 10 feet of the location designated
for the VRC installation. |
|
|
|
|
|
|
|
|
|
|
2.04:
FINISHES |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
A.
All carbon steel surfaces shall be coated with an industrial
enamel finish - color slate gray and black. |
|
|
B.
Prior to applying finish, all dirt, mill scale, oil and
grease shall be removed from carbon steel surfaces
by a combination of brushing, wiping and use of solvents. |
|
|
|
|
|
|
|
|
|
|
|
PART
3: EXECUTION |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
3.01:
EXAMINATION |
|
|
|
|
|
|
|
A.
Prior to commencing installation of the VRC, the installer
shall visually examine the conditions under which
the VRC is to be installed and notify the architect in
writing of conditions detrimental to the proper and timely
completion of the work. |
|
|
|
|
|
|
|
|
|
|
|
3.02:
INSTALLATION |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
A.
Installer must comply with manufacturer's detailed mechanical
and electrical installation instructions for proper
installation and to meet safety codes. All thresholds
and extra installation materials needed must be supplied
by the installer. |
|
|
|
|
|
|
|
|
|
|
3.03:
FIELD QUALITY CONTROL |
|
|
|
|
|
A.
Inspection: Upon completion of installation, the VRC shall
be inspected to verify that it meets all
requirements set forth by FSI and Parts 1, 2 and 3 of
this Section. |
|
|
|
|
|
|
|
|
|
|
|
|
B.
Tests: |
|
|
|
1.
Operating Load Test: The owner will provide a _______
pound test load and load the VRC at the lowest
level. The loaded VRC carriage shall be conveyed to an
upper floor level and returned to the lowest level to
assure proper operation. If the VRC cannot lift or lower
the load, the VRC shall fail the test. |
|
|
|
2.
Performance Test: This test is to be performed in conjunction
with Test 1 above. During the demonstration
of the lifting and lowering test, the owner shall measure
the time required to lift and lower the capacity load.
The owner will average times for lifting and lowering
the load and calculate the average feet per minute travel
speed. If the VRC does not lift the load within 10% of
the specified speed, or if the lowering speed exceeds
the lifting speed by more than 10%, the VRC shall fail
the test. |
|
|
|
3.
Stationary Load Test: This test is to be performed in
conjunction with Test 1 above. The loaded VRC
carriage shall remain stationary at an upper level for
a minimum of one (1) hour. After the one (1) hour period,
the VRC will be inspected for deflection of the components
or drift of the platform. If deformation or downward
drift is evident, the VRC shall fail the test. |
|
|
|
|
|
|
|
|
|
|
|
3.04:
ADJUSTING AND CLEANUP |
|
|
|
|
A.
Installer shall touch up all scratches, abrasions, and
other defects in the pre-finished surfaces with the same
material color and type of finish as that used at time
of fabrication. |
|
|
B.
Installer will remove and dispose of all rubbish and debris
caused by the work under this section. |
|
|
C.
Verification that equipment is properly installed in accordance
with manufacturer's guidelines and guarded to
meet or exceed ANSI/ASME B20.1 Safety Standards for Conveyors. |
|
Dual
Mast Mezzanine Lift, Mezzanine Material Lifts, Custom
Industrial Material Lift, Vertical Conveyor, Freight Elevator,
Vertical Material Lifts, Vertical Platform Lifts, Vertical
Reciprocating Conveyor, Pallet Master, and VRC form your
source for material handling equipment. |
|
Back
to Product Category
Back
to Product Category |
|
|