Commercial
Low Profile 8 Air Curtains |
Electric
Heated |
|
|
|
|
|
Saving
Energy and Creating Healthy, Comfortable Environments |
|
|
|
|
|
|
Low
profile air curtain with white or black powder coated cabinet,
requires a minimum of 9.5 clearance above the door.
Available in single lengths from 2 ½ to 10.
Custom Colors or Stainless Steel available. |
|
|
|
|
IDEAL APPLICATIONS: |
|
|
Service / Employee
Doors
Main Entrances
Concessions / Drive-Thrus
Shopping Carts
Walk-in Coolers |
|
|
|
|
Series
#CLC08E |
|
|
|
|
|
|
|
For
mounting heights up to 8' (environmental separation) and 7'
(insect control) |
|
|
|
|
Standard
Construction |
|
Installation
& Mounting |
8 ½ high x 13 ½ deep
1/5 hp two speed motor(s)
Factory installed fan speed switch
White or black powder coated exterior
Wall & Top Mounting |
|
Simple
to install, operate & maintain |
|
|
|
|
Single lengths up to 10
No Assembly Required
Wall plate included
1/4 threaded inserts for top mounting
Bottom access panel for easy access to internal
components |
Open helical element with point suspension |
|
|
|
Control
Packages: |
|
|
|
|
Deluxe |
|
|
|
|
|
|
|
Building
Automation & Door Controller versions available. |
|
|
|
|
|
|
|
Air
curtains provide environmental separation at
openings by reducing the infiltration of unconditioned
air, fumes, dust, and humidity. At exterior openings,
they can resist winds up to 8 MPH (13 KPH) and are
generally mounted inside the building. During cold
seasons warm air that has risen towards ceiling is re-
circulated; they can also be used at interior openings
such as doors to coolers or clean rooms. Optimum
protection is provided when units are mounted flush
to the wall and as close to top of door opening as
possible. To ensure peak performance keep air
stream free of obstructions. Air curtains may not
be fully effective where negative air pressure exists
on one side of door. |
|
|
|
|
Series
CLC08 model air curtains have 1/5 HP motors.
They can be wall mounted or suspended from the
ceiling. Electric heated units shall be installed indoors
only and require - a minimum clearance of at least 6 ft
(182.9 cm) between the bottom of the unit and the
floor, a minimum of 4 in (10.2 cm) between the top
and ceiling and 1 in (2.5 cm) between the sides and any
combustible material. |
|
|
|
COMMERCIAL
LOW PROFILE 8 Electric Heated Air Curtain Data Sheet |
MODEL |
Nozzle
Width
(in) |
Max
Vel. at
Nozzle
(fpm) |
Avg.
Outlet
Vel.
(fpm) |
Air
Volume
(cfm) |
Outlet
Vel.
Uniformity |
Power
Rating
(kW) |
Motor(s)
@ hp |
Max
Electric
Cap. (kW) |
Heater
Output
(MBH) |
Air
Temp.
Rise
(°F) |
Net
Wt.
(lbs) |
CLC08-1036E |
34.62 |
3,567 |
1,760 |
1,005 |
92% |
0.32 |
1
@ 1/5
| 10 |
34.1 |
31° |
48 |
CLC08-1042E |
40.62 |
3,388 |
1,755 |
1,176 |
93% |
0.32 |
1
@ 1/5
| 10 |
34.1 |
27° |
53 |
CLC08-1048E |
46.62 |
3,226 |
1,742 |
1,340 |
94% |
0.32 |
1
@ 1/5
| 14.4 |
49.1 |
34° |
58 |
CLC08-1060E |
58.13 |
2,940 |
1,702 |
1,632 |
95% |
0.32 |
1
@ 1/5
| 14.4 |
49.1 |
28° |
67 |
CLC08-1072E |
71.37 |
2,870 |
1,707 |
2,010 |
95% |
0.32 |
1
@ 1/5
| 20 |
68.3 |
31° |
77 |
CLC08-2084E |
83.5 |
3,388 |
1,707 |
2,351 |
93% |
0.64 |
2
@ 1/5
| 20 |
68.3 |
27° |
105 |
CLC08-2096E |
95.5 |
3,226 |
1,701 |
2,679 |
94% |
0.64 |
2
@ 1/5
| 28.8 |
98.3 |
34° |
115 |
CLC08-2108E |
107 |
3,226 |
1,684 |
2,971 |
94% |
0.64 |
2
@ 1/5
| 28.8 |
98.3 |
30° |
123 |
CLC08-2120E |
118.5 |
2,940 |
1,670 |
3,263 |
95% |
0.64 |
2
@ 1/5
| 28.8 |
98.3 |
28° |
137 |
|
NOTE:
1. Operation at 50 Hz will generate approximately a 17% reduction in performance.
2. Performance data based on unheated units.
3. Consult factory for vertically mounted units. |
|
|
|
|
COMMERCIAL
LOW PROFILE 8 Electric Heated Air Curtain Electrical Perf. Sheet |
|
208/3/60
(voltage code X) |
240/3/60
(voltage code Y) |
480/3/60
(voltage code Z) |
|
MOTOR
AMP DRAW = 1.7 each |
MOTOR
AMP DRAW = 1.7 each |
MOTOR
AMP DRAW = 0.9 each |
MODEL |
kW
(suffix) |
Temp
Rise
°F |
#
CKTS |
AMPS
PER
CIRCUIT
(including
motor) |
BREAKER
RATING PER CIRCUIT |
#
CKTS |
AMPS
PER
CIRCUIT
(including
motor) |
BREAKER
RATING
PER
CIRCUIT |
#
CKTS |
AMPS
PER
CIRCUIT
(including
motor) |
BREAKER
RATING
PER
CIRCUIT |
CLC08-1036E
CLC08-1042E |
10
(100)
| 31 |
1 |
29.5 |
40 |
1 |
25.8 |
35 |
1 |
12.9 |
20 |
7.5
(075)
| 23 |
1 |
22.5 |
30 |
1 |
19.7 |
25 |
1 |
9.9 |
15 |
5.6
(056)
| 18 |
1 |
17.2 |
25 |
1 |
15.2 |
20 |
- |
N/A |
N/A |
4
(040) |
13 |
1 |
12.8 |
20 |
- |
N/A |
N/A |
- |
N/A |
N/A |
CLC08-1048E
CLC08-1060E |
14.4
(144)
| 34 |
1 |
41.7 |
60 |
1 |
36.3 |
50 |
1 |
18.2 |
25 |
10.8
(108)
| 25 |
1 |
31.7 |
40 |
1 |
27.7 |
35 |
1 |
13.9 |
20 |
8.1
(081)
| 19 |
1 |
24.2 |
35 |
1 |
21.2 |
30 |
- |
N/A |
N/A |
5.6
(056)
| 13 |
1 |
17.2 |
25 |
- |
N/A |
N/A |
- |
N/A |
N/A |
CLC08-1072E |
20
(200)
| 31 |
2 |
29.5/27.8
| 40/35 |
2 |
25.8/24.1
| 35/35 |
1 |
25.0 |
35 |
15
(150)
| 23 |
1 |
43.3 |
60 |
1 |
37.8 |
50 |
1 |
18.9 |
25 |
11.2
(112)
| 18 |
1 |
32.8 |
45 |
1 |
28.6 |
40 |
- |
N/A |
N/A |
8
(080) |
13 |
1 |
23.9 |
30 |
- |
N/A |
N/A |
- |
N/A |
N/A |
CLC08-2084E |
20
(200)
| 27 |
2 |
31.2/27.8
| 40/35 |
2 |
27.5/24.1
| 35/35 |
1 |
25.9 |
35 |
15
(150)
| 20 |
1 |
45 |
60 |
1 |
39.5 |
50 |
1 |
19.8 |
25 |
11.2
(112)
| 15 |
1 |
34.5 |
45 |
1 |
30.3 |
40 |
- |
N/A |
N/A |
8
(080) |
11 |
1 |
25.6 |
35 |
- |
N/A |
N/A |
- |
N/A |
N/A |
CLC08-2096E
CLC08-2108E
CLC08-2120E |
28.8
(288)
| 34 |
2 |
43.4/40.0
| 60/50 |
2 |
38.0/34.6
| 50/45 |
1 |
36.4 |
50 |
21.6
(216)
| 25 |
2 |
33.4/30.0
| 45/40 |
2 |
29.4/26.0
| 40/35 |
1 |
27.08 |
35 |
16.2
(162)
| 19 |
1 |
48.4 |
60 |
1 |
42.4 |
60 |
- |
N/A |
N/A |
11.2
(112)
| 13 |
1 |
34.5 |
45 |
- |
N/A |
N/A |
- |
N/A |
N/A |
|
|
|
|
|
|
|
|
|
|
NOTE: |
|
|
|
|
1.
Air curtain must be installed so air stream is not obstructed when deflected
20° to either side of C. |
|
|
2.
Electrical connections to be flexible. |
|
|
|
|
3.
Field verify dimensions. |
|
|
|
|
4.
Anchors to supporting structure by others. |
|
|
|
|
5.
Adequacy of supporting structure is to be verified by a professional structural
engineer. |
|
6. Letter "E" in model number designates electric heated unit. |
|
|
|
7.
Dimensions in inches [centimeters]. |
|
|
|
|
|
|
|
|
Order
Online, by Phone, or by E-Mail |
|
|
|
~ Add
items to your online shopping cart ~
Click the Model No. of the item you wish
to purchase. |
|
|
|
|
|
|
PRICING
FOR COMMERCIAL LOW PROFILE 8 ELECTRIC HEATED AIR CURTAIN |
MODEL
# |
208-240/3/60
Price
| MODEL
# |
480/3/60
Price |
Std.
Elec.
kW |
Shipping
Wt. (lbs.) |
|
$2,535 |
|
$2,979 |
10.0 |
58 |
|
$2,558 |
|
$3,002 |
10.0 |
64 |
|
$2,647 |
|
$3,099 |
14.4 |
67 |
|
$2,747 |
|
$3,194 |
14.4 |
78 |
|
$2,899 |
|
$3,949 |
20.0 |
88 |
|
$3,800 |
|
$5,103 |
20.0 |
127 |
|
$4,523 |
|
$5,039 |
28.8 |
137 |
|
$4,649 |
|
$5,175 |
28.8 |
146 |
|
$4,686 |
|
$5,240 |
28.8 |
157 |
|
OPTIONS |
Model
No. |
Description |
Price |
| Deluxe
Low Voltage Control (includes time delay relay,
24 volt control transfomer, and magentic reed door switch) |
$398 |
|
Model
No. |
Description |
Price |
|
Thermostat |
$77 |
|
|
|
Low Profile 8 Electric Heated
Air Curtains, Air Curtains, Commercial Air Curtain, Commercial Air Door,
Electric Heated Air Curtains,
and Insect Barrier from your source for material handling equipment. |
|