Loads
shown in the tables below are the allowable uniform loads
in pounds per square foot (kilopascals).
•
For
spans of 4 ft 6 in. (1.37 m) and over, loads that are in brackets
indicate that the allowable total load shown
is limited to the live load, producing a deflection equal
to the span/240 plus 10 psf (0.5 kPa). For spans of less
than 4 ft 6 in. (1.37 m), loads that are in brackets indicate
that the allowable total load shown is limited by web
crippling instead of bending.
Service
Load Tables (psf)
Type
Nominal
Thick (in.)
SINGLE SPAN (ft)
4.00
4.50
5.00
5.50
6.00
6.50
7.00
7.50
8.00
8.50
9.00
9.50
10.00
22
0.030
150
(117)
(88)
(69)
(55)
(46)
20
0.036
183
145
(110)
(85)
(68)
(56)
(46)
18
0.048
251
198
(154)
(118)
(94)
(76)
(63)
(53)
(45)
16
0.060
315
249
(192)
(147)
(115)
(93)
(76)
(64)
(54)
(47)
(41)
Type
Nominal
Thick (in.)
DOUBLE SPAN (ft)
4.00
4.50
5.00
5.50
6.00
6.50
7.00
7.50
8.00
8.50
9.00
9.50
10.00
22
0.030
152
121
98
81
69
59
51
44
20
0.036
186
148
120
100
84
72
62
54
47
42
18
0.048
256
203
164
136
114
97
84
73
64
57
51
45
41
16
0.060
318
251
204
168
141
120
104
90
80
70
63
56
51
Type
Nominal
Thick (in.)
TRIPLE SPAN (ft)
4.00
4.50
5.00
5.50
6.00
6.50
7.00
7.50
8.00
8.50
9.00
9.50
10.00
22
0.030
188
148
120
99
83
71
61
53
(46)
(40)
20
0.036
229
181
146
121
102
87
75
65
(56)
(48)
(42)
18
0.048
313
247
200
166
139
119
102
89
(76)
(65)
(57)
(50)
(44)
16
0.060
394
312
252
209
175
149
129
(112)
(94)
(80)
(69)
(60)
(53)
Service
Load Tables (kPa)
Type
Nominal
Thick (mm)
SINGLE SPAN (mm)
1200
1350
1500
1650
1800
1950
2100
2250
2400
2550
2700
2850
3000
22
0.76
7.42
5.86
(4.41)
(3.43)
(2.75)
(2.27)
20
0.91
9.04
7.15
(5.50)
(4.25)
(3.39)
(2.77)
(2.31)
(1.97)
18
1.21
12.38
9.78
(7.72)
(5.92)
(4.67)
(3.78)
(3.12)
(2.63)
(2.25)
(1.95)
16
1.52
15.59
12.32
(9.61)
(7.34)
(5.76)
(4.64)
(3.81)
(3.18)
(2.71)
(2.34)
(2.04)
Type
Nominal
Thick (mm)
DOUBLE SPAN (mm)
1200
1350
1500
1650
1800
1950
2100
2250
2400
2550
2700
2850
3000
22
0.76
7.52
5.97
4.85
4.02
3.39
2.89
2.50
2.18
1.92
20
0.91
9.19
7.30
5.93
4.92
4.14
3.53
3.05
2.66
2.34
2.07
18
1.21
12.67
10.01
8.11
6.70
5.63
4.80
4.14
3.60
3.17
2.81
2.50
2.25
2.03
16
1.52
15.72
12.42
10.06
8.32
6.99
5.95
5.13
4.47
3.93
3.48
3.11
2.79
2.52
Type
Nominal
Thick (mm)
TRIPLE SPAN (mm)
1200
1350
1500
1650
1800
1950
2100
2250
2400
2550
2700
2850
3000
22
0.76
9.27
7.33
5.94
4.91
4.12
3.51
3.03
2.64
(2.29)
(1.99)
20
0.91
11.31
8.93
7.24
5.98
5.02
4.28
3.69
3.22
(2.79)
(2.41)
(2.10)
18
1.21
15.47
12.23
9.90
8.18
6.88
5.86
5.05
4.40
(3.82)
(3.26)
(2.82)
(2.47)
(2.19)
16
1.52
19.49
15.40
12.47
10.31
8.66
7.38
6.36
5.54
(4.69)
(3.99)
(3.43)
(2.99)
(2.63)
Physical
Properties
Nominal
Thickness
Design
Thickness
Overall
Depth
Weight
Allowable Reaction
Section Modules
Moment
of Inertia
Bearing 3 in. (76mm)
M+
M-
end
interior
Type
in.
in.
in.
lb/ft2
lb
lb
in.3
in.3
in.4
(mm)
(mm)
(mm)
(kg/m2)
(kN)
(kN)
(mm3)
(mm3)
(mm4)
22
0.030
0.0300
1.49
1.68
485
954
0.178
0.185
0.148
(0.76)
(0.762)
(37.7)
(8.22)
(7.08)
(13.92)
(9580)
(9961)
(202100)
20
0.036
0.0358
1.49
2.01
649
1,433
0.217
0.226
0.189
(0.91)
(0.909)
(37.8)
(9.83)
(9.47)
(20.91)
(11680)
(12165)
(258530)
18
0.048
0.0479
1.50
2.66
1,037
2,631
0.297
0.304
0.273
(1.21)
(1.217)
(38.1)
(12.97)
(15.14)
(38.39)
(15984)
(16365)
(372703)
16
0.060
0.0595
1.51
3.33
1,848
4,075
0.374
0.378
0.344
(1.52)
(1.511)
(38.5)
(16.22)
(26.98)
(59.47)
(20131)
(20302)
(469816)
Properties
are based on a unit width of 12 in. for imperial units and
a unit width of 1000 mm for S.I. units.
The properties in the table were calculated according to AISI
1996 Specification for the Design of Cold-Formed
Steel Structural Members, considering steel produced according
to ASTM A 653 SS Grade 33,
yield strength = 33 ksi (230 MPa).
Installation
Steel
deck sheets lap one another side to side and length to length.
Deck is fastened to suggested methods of deck
fastening supports using 12-24 x 1 ¼" TEK #5 screws
(C10 optional). End of deck panels should have a screw (C10)
in each corrugation touching the supports and they should
be installed in alternate corrugations where they meet the
channels along the interior length of the deck panel. NOTE:
If screws are used to attach deck to supports, a
12-24 x 1 ¼" TEK #5 is advised. If deck is welded
then Arc Puddle Welds are generally the most efficient and
economical method of attaching steel deck to structural supports.
Either E60XX or E70XX welding rods are
recommended and the amperage must be adjusted to individual
jobsite requirements: the American Welding Society
Specifications for Welding Sheet Steel in Structures should
be followed.
Corrugated
Steel Decking, B Deck, Mezzanine Decking, ResinDek, Drill
Screw Fasteners, Mezzanine Flooring, Deck Panels,
Galvanized B Deck, and Roof Deck from your source for material